Extended Coverage Ionizing Air Blower

Extended Coverage Ionizing Air Blower

Extended Coverage Ionizing Air Blower

DF711W Type

The use of AC ionization technology and large coverage design, 0+/-10V instinctive balance circuit, built-in cleaning brush and high voltage ionization indicator light, provide stable ion balance and fast static elimination, can be applied in different electronic and medical equipment production environments, protect electronic components that are extremely sensitive to static damage, can also prevent dust particles from adsorbing on the product, and provide warm air to make operators feel comfortable.

Features:
  • Large coverage and fast static elimination, no blind area through the long air outlet
  • Built-in ionic needle cleaning brush simplifies maintenance
  • Ion work indicator for easy confirmation of ion output
  • Heater heating for operator comfort
  • Stable ion balance for protection of electrostatically sensitive electronic components
  • The size of the wind can be adjusted, and the air volume can be controlled at will
ESD protection standards

ESD protection standards

The ability of the static eliminator is tested by the United States EOS/ES!standard for the use of a live flat panel monitor, and the residual voltagestandard specifies between +35V and the static dissipation time reflectsthe speed at which the static electricity is removed.

Is has a warm air heating function

It comes with warm air heating, which makes the operator more comfortable in winter. The products are used in a wide range of applications, from electronic and medical device assembly to testing and packaging; It is more commonly used in the assembly and testing of components in the flat panel display industry.

Is has a warm air heating function
Typical dissipation time

Typical dissipation time

According to the United States ESD Institute standard: ANS!/ESDS20.202014 standard, each point represents the static dissipation time from1000V to 100V at high wind speeds.

Test instrument: CPM374

  • Test voltage: +1000V-+100V attenuation
  • Measure distances: 30CM
  • Measurement environment: humidity 55%, temperature 25°C